Refine
FILTERSClear All

Inlet Port

Outlet Port

Element Length

Inlet Port Type

Outlet Port Type

Operating Temperature

Seals

Click Image to Zoom
RFP Series Moduflow™ Plus Return-line Low Pressure FilterRFP Series Moduflow™ Plus Return-line Low Pressure Filter

RFP Series Moduflow™ Plus Return-line Low Pressure Filter

Parker RFP Series Moduflow™ Plus Return-line Hydraulic and Lube Oil Low Pressure Filter

Email this page to a friend


Showing 1 - 12 of 12  
Part # Availability Price/UOM
++ RFP105QBPE35P9F81 Out of Stock - Lead Time Required $680.57
++ RFP105QBPE35P9F91 Out of Stock - Lead Time Required $568.69
++ RFP105QBPE35Y9991 Out of Stock - Lead Time Required $492.92
++ RFP105QVPE35P9F81 Out of Stock - Lead Time Required $752.12
++ RFP105QVPE35P9F91 Out of Stock - Lead Time Required $640.25
++ RFP105QVPE35Y9991 Out of Stock - Lead Time Required $541.66
++ RFP205QBPE35P9F81 Out of Stock - Lead Time Required $718.23
++ RFP205QBPE35P9F91 Out of Stock - Lead Time Required $606.35
++ RFP205QBPE35Y9991 Out of Stock - Lead Time Required $530.58
++ RFP205QVPE35P9F81 Out of Stock - Lead Time Required $789.78
++ RFP205QVPE35P9F91 Out of Stock - Lead Time Required $677.91
++ RFP205QVPE35Y9991 Out of Stock - Lead Time Required $579.32
UOM Inlet Port Outlet Port Element Length Nominal Filter Rating Nominal Flow Rating Indicator Type Bypass Options Max Pressure - Fatigue MAOP Max Pressure - Non-Fatigue MAOP Seals Operating Temperature Replacement Element Country of Origin (COO) Harmonized Tariff (HTS)
EA 24 SAE External check valve Single 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Nitrile -40F to 225F (-40C to 107C) 937394Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE 2 NPT Single 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Nitrile -40F to 225F (-40C to 107C) 937394Q Special request, please call for COO Special request, please call for HTS
EA 2" flange face Blank flange Single 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Nitrile -40F to 225F (-40C to 107C) 937394Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE External check valve Single 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Fluorocarbon -15F to 275F (-26C to 135C) 937402Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE 2 NPT Single 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Fluorocarbon -15F to 275F (-26C to 135C) 937402Q Special request, please call for COO Special request, please call for HTS
EA 2" flange face Blank flange Single 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Fluorocarbon -15F to 275F (-26C to 135C) 937402Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE External check valve Double 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Nitrile -40F to 225F (-40C to 107C) 937398Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE 2 NPT Double 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Nitrile -40F to 225F (-40C to 107C) 937398Q Special request, please call for COO Special request, please call for HTS
EA 2" flange face Blank flange Double 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Nitrile -40F to 225F (-40C to 107C) 937398Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE External check valve Double 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Fluorocarbon -15F to 275F (-26C to 135C) 937406Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE 2 NPT Double 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Fluorocarbon -15F to 275F (-26C to 135C) 937406Q Special request, please call for COO Special request, please call for HTS
EA 2" flange face Blank flange Double 5 micron 150 GPM (581 LPM) Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right) 35 PSI (2.4 bar) No Option 150 PSI (10.3 bar) 200 PSI (13.8 bar) Fluorocarbon -15F to 275F (-26C to 135C) 937406Q Special request, please call for COO Special request, please call for HTS
RFP105QBPE35P9F81
Out of Stock - Lead Time Required
$680.57

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

External check valve

Single

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Nitrile

-40F to 225F (-40C to 107C)

937394Q

Special request, please call for COO

Special request, please call for HTS

RFP105QBPE35P9F91
Out of Stock - Lead Time Required
$568.69

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

2 NPT

Single

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Nitrile

-40F to 225F (-40C to 107C)

937394Q

Special request, please call for COO

Special request, please call for HTS

RFP105QBPE35Y9991
Out of Stock - Lead Time Required
$492.92

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2" flange face

Blank flange

Single

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Nitrile

-40F to 225F (-40C to 107C)

937394Q

Special request, please call for COO

Special request, please call for HTS

RFP105QVPE35P9F81
Out of Stock - Lead Time Required
$752.12

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

External check valve

Single

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Fluorocarbon

-15F to 275F (-26C to 135C)

937402Q

Special request, please call for COO

Special request, please call for HTS

RFP105QVPE35P9F91
Out of Stock - Lead Time Required
$640.25

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

2 NPT

Single

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Fluorocarbon

-15F to 275F (-26C to 135C)

937402Q

Special request, please call for COO

Special request, please call for HTS

RFP105QVPE35Y9991
Out of Stock - Lead Time Required
$541.66

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2" flange face

Blank flange

Single

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Fluorocarbon

-15F to 275F (-26C to 135C)

937402Q

Special request, please call for COO

Special request, please call for HTS

RFP205QBPE35P9F81
Out of Stock - Lead Time Required
$718.23

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

External check valve

Double

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Nitrile

-40F to 225F (-40C to 107C)

937398Q

Special request, please call for COO

Special request, please call for HTS

RFP205QBPE35P9F91
Out of Stock - Lead Time Required
$606.35

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

2 NPT

Double

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Nitrile

-40F to 225F (-40C to 107C)

937398Q

Special request, please call for COO

Special request, please call for HTS

RFP205QBPE35Y9991
Out of Stock - Lead Time Required
$530.58

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2" flange face

Blank flange

Double

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Nitrile

-40F to 225F (-40C to 107C)

937398Q

Special request, please call for COO

Special request, please call for HTS

RFP205QVPE35P9F81
Out of Stock - Lead Time Required
$789.78

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

External check valve

Double

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Fluorocarbon

-15F to 275F (-26C to 135C)

937406Q

Special request, please call for COO

Special request, please call for HTS

RFP205QVPE35P9F91
Out of Stock - Lead Time Required
$677.91

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

2 NPT

Double

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Fluorocarbon

-15F to 275F (-26C to 135C)

937406Q

Special request, please call for COO

Special request, please call for HTS

RFP205QVPE35Y9991
Out of Stock - Lead Time Required
$579.32

UOM:

Inlet Port:

Outlet Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2" flange face

Blank flange

Double

5 micron

150 GPM (581 LPM)

Pressure ports drilled & plugged only, no indicator (left) electrical indicator only (right)

35 PSI (2.4 bar)

No Option

150 PSI (10.3 bar)

200 PSI (13.8 bar)

Fluorocarbon

-15F to 275F (-26C to 135C)

937406Q

Special request, please call for COO

Special request, please call for HTS

Showing 1 - 12 of 12
Parker RFP Series Moduflow™ Plus Return-line Hydraulic and Lube Oil Low Pressure Filter

Application: Power unit fabrication, off-line filter loops and mobile equipment.
Updating...