Refine
FILTERSClear All

Port

Nominal Filter Micron Rating

Filter Media Type

Port Type

Filter Media Code

Gauge Port Location

Click Image to Zoom
50AT Series Low Pressure Filter50AT Series Low Pressure Filter

50AT Series Low Pressure Filter

Parker 50AT Series Hydraulic and Lube Oil Low Pressure Filter

Email this page to a friend


Showing 1 - 7 of 7  
Part # Availability Price/UOM
50AT210CN3DDN N/A Discontinued
50AT210CN3DDH N/A Discontinued
50AT210BN3DDH N/A Discontinued
50AT220BN3DDH N/A Discontinued
50AT210CN3OOH N/A Discontinued
50AT210BN3OOH N/A Discontinued
50AT220BN3OOH N/A Discontinued
UOM Port Element Length Nominal Filter Rating Nominal Flow Rating Indicator Type Bypass Gauge Port Location Max Pressure - Non-Fatigue MAOP Seals Operating Temperature Replacement Element Country of Origin (COO) Harmonized Tariff (HTS)
EA 1 1/4 NPT Double 10 micron 40 GPM (152 LPM) No Indicator 3 PSI (0.2 bar) No Gauge Port 150 psi (10.3 bar) Nitrile -40F to 225F (-40C to 107C) 927736 Special request, please call for COO Special request, please call for HTS
EA 1 1/4 NPT Double 10 micron 40 GPM (152 LPM) No Indicator 3 PSI (0.2 bar) Inlet And Outlet - Both Sides 150 psi (10.3 bar) Nitrile -40F to 225F (-40C to 107C) 927736 Special request, please call for COO Special request, please call for HTS
EA 1 1/4 NPT Double 10 micron 40 GPM (152 LPM) No Indicator 3 PSI (0.2 bar) Inlet And Outlet - Both Sides 150 psi (10.3 bar) Nitrile -40F to 225F (-40C to 107C) 929445 Special request, please call for COO Special request, please call for HTS
EA 1 1/4 NPT Double 20 micron 40 GPM (152 LPM) No Indicator 3 PSI (0.2 bar) Inlet And Outlet - Both Sides 150 psi (10.3 bar) Nitrile -40F to 225F (-40C to 107C) 929446 Special request, please call for COO Special request, please call for HTS
EA 20 SAE Double 10 micron 40 GPM (152 LPM) No Indicator 3 PSI (0.2 bar) Inlet And Outlet - Both Sides 150 psi (10.3 bar) Nitrile -40F to 225F (-40C to 107C) 927736 Special request, please call for COO Special request, please call for HTS
EA 20 SAE Double 10 micron 40 GPM (152 LPM) No Indicator 3 PSI (0.2 bar) Inlet And Outlet - Both Sides 150 psi (10.3 bar) Nitrile -40F to 225F (-40C to 107C) 929445 Special request, please call for COO Special request, please call for HTS
EA 20 SAE Double 20 micron 40 GPM (152 LPM) No Indicator 3 PSI (0.2 bar) Inlet And Outlet - Both Sides 150 psi (10.3 bar) Nitrile -40F to 225F (-40C to 107C) 929446 Special request, please call for COO Special request, please call for HTS
50AT210CN3DDN
N/A

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Gauge Port Location:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/4 NPT

Double

10 micron

40 GPM (152 LPM)

No Indicator

3 PSI (0.2 bar)

No Gauge Port

150 psi (10.3 bar)

Nitrile

-40F to 225F (-40C to 107C)

927736

Special request, please call for COO

Special request, please call for HTS

50AT210CN3DDH
N/A

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Gauge Port Location:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/4 NPT

Double

10 micron

40 GPM (152 LPM)

No Indicator

3 PSI (0.2 bar)

Inlet And Outlet - Both Sides

150 psi (10.3 bar)

Nitrile

-40F to 225F (-40C to 107C)

927736

Special request, please call for COO

Special request, please call for HTS

50AT210BN3DDH
N/A

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Gauge Port Location:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/4 NPT

Double

10 micron

40 GPM (152 LPM)

No Indicator

3 PSI (0.2 bar)

Inlet And Outlet - Both Sides

150 psi (10.3 bar)

Nitrile

-40F to 225F (-40C to 107C)

929445

Special request, please call for COO

Special request, please call for HTS

50AT220BN3DDH
N/A

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Gauge Port Location:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/4 NPT

Double

20 micron

40 GPM (152 LPM)

No Indicator

3 PSI (0.2 bar)

Inlet And Outlet - Both Sides

150 psi (10.3 bar)

Nitrile

-40F to 225F (-40C to 107C)

929446

Special request, please call for COO

Special request, please call for HTS

50AT210CN3OOH
N/A

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Gauge Port Location:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

20 SAE

Double

10 micron

40 GPM (152 LPM)

No Indicator

3 PSI (0.2 bar)

Inlet And Outlet - Both Sides

150 psi (10.3 bar)

Nitrile

-40F to 225F (-40C to 107C)

927736

Special request, please call for COO

Special request, please call for HTS

50AT210BN3OOH
N/A

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Gauge Port Location:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

20 SAE

Double

10 micron

40 GPM (152 LPM)

No Indicator

3 PSI (0.2 bar)

Inlet And Outlet - Both Sides

150 psi (10.3 bar)

Nitrile

-40F to 225F (-40C to 107C)

929445

Special request, please call for COO

Special request, please call for HTS

50AT220BN3OOH
N/A

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Gauge Port Location:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

20 SAE

Double

20 micron

40 GPM (152 LPM)

No Indicator

3 PSI (0.2 bar)

Inlet And Outlet - Both Sides

150 psi (10.3 bar)

Nitrile

-40F to 225F (-40C to 107C)

929446

Special request, please call for COO

Special request, please call for HTS

Showing 1 - 7 of 7