Refine
FILTERSClear All

Port

Port Type

Options

Click Image to Zoom
50CS Series Medium Pressure Filter50CS Series Medium Pressure Filter

50CS Series Medium Pressure Filter

Parker 50CS Series Hydraulic and Lube Oil Medium Pressure Filter

Email this page to a friend


Showing 1 - 12 of 12  
Part # Availability Price/UOM
++ 50CS110QEBMLKN161 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKN164 Out of Stock - Lead Time Required $315.18
++ 50CS110QEBMLKN201 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKN204 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKN241 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKN244 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKS161 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKS164 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKS201 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKS204 In Stock $305.72
++ 50CS110QEBMLKS241 Out of Stock - Lead Time Required $305.72
++ 50CS110QEBMLKS244 Out of Stock - Lead Time Required $305.72
UOM Port Element Length Nominal Filter Rating Nominal Flow Rating Indicator Type Bypass Options Max Pressure - Fatigue MAOP Max Pressure - Non-Fatigue MAOP Seals Operating Temperature Replacement Element Country of Origin (COO) Harmonized Tariff (HTS)
EA 1 NPT Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) No Option 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 1 NPT Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) Drain Port 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 1 1/4 NPT Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) No Option 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 1 1/4 NPT Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) Drain Port 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 NPT Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) No Option 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 NPT Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) Drain Port 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 16 SAE Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) No Option 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 16 SAE Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) Drain Port 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 20 SAE Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) No Option 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 20 SAE Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) Drain Port 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) No Option 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
EA 24 SAE Single 10 micron 50 GPM ( 189 LPM) Visual indicator - Push to Test, Left 50 PSI (3.5 bar) Drain Port 400 PSI (27.6 Bar) 500 PSI (34.5 bar) Nitrile -40F to 225F (-40C to 107C) 940818Q Special request, please call for COO Special request, please call for HTS
50CS110QEBMLKN161
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 NPT

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

No Option

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKN164
Out of Stock - Lead Time Required
$315.18

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 NPT

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

Drain Port

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKN201
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/4 NPT

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

No Option

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKN204
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/4 NPT

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

Drain Port

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKN241
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 NPT

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

No Option

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKN244
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 NPT

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

Drain Port

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKS161
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

16 SAE

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

No Option

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKS164
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

16 SAE

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

Drain Port

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKS201
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

20 SAE

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

No Option

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKS204
In Stock
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

20 SAE

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

Drain Port

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKS241
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

No Option

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

50CS110QEBMLKS244
Out of Stock - Lead Time Required
$305.72

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

24 SAE

Single

10 micron

50 GPM ( 189 LPM)

Visual indicator - Push to Test, Left

50 PSI (3.5 bar)

Drain Port

400 PSI (27.6 Bar)

500 PSI (34.5 bar)

Nitrile

-40F to 225F (-40C to 107C)

940818Q

Special request, please call for COO

Special request, please call for HTS

Showing 1 - 12 of 12
Parker 50CS Series Hydraulic and Lube Oil Medium Pressure Filter

Application: Mobile ag, mobile construction, material handlers, aerial lifts, pilot lines, charge pump hydrostatic drives, industrial power units, machine tools and joy stick controls.
Updating...