Part # Availability Price/UOM
++ 80CN102QEBE2KY324 Out of Stock - Lead Time Required $874.24
++ 80CN110QEBM2KY324 Out of Stock - Lead Time Required $809.23
80CN202QEBE2KY324 N/A Call to Order
++ 80CN205QEBE2KY324 Out of Stock - Lead Time Required $936.97
80CN205QEBM2KY324 N/A Call to Order
++ 80CN210QEBE2KY324 Out of Stock - Lead Time Required $928.19
80CN210QEBM2KY324 N/A Call to Order
80CN220QEBE2KY324 N/A Call to Order
80CN220QEBM2KY324 N/A Call to Order
80CN110QEBM2KN324 N/A Call to Order
80CN120QEBM2KN324 N/A Call to Order
80CN202QEBM2KN324 N/A Call to Order
80CN205QEBM2KN324 N/A Call to Order
++ 80CN210QEBM2KN324 Out of Stock - Lead Time Required $890.34
++ 80CN220QEBM2KN324 Out of Stock - Lead Time Required $852.66
80CN102QEBM2KN244 N/A Call to Order
++ 80CN105QEBM2KN244 Out of Stock - Lead Time Required $809.09
++ 80CN105QEBPKN244 Out of Stock - Lead Time Required $743.83
80CN120QEBE2KN244 N/A Call to Order
80CN120QEBM2KN244 N/A Call to Order
UOM Port Element Length Nominal Filter Rating Nominal Flow Rating Indicator Type Bypass Options Max Pressure - Fatigue MAOP Max Pressure - Non-Fatigue MAOP Seals Operating Temperature Replacement Element Country of Origin (COO) Harmonized Tariff (HTS)
EA 2 Flange face - SAE Code 61 Single 2 micron 45 GPM (171 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936713Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Single 10 micron 45 GPM (171 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936602Q United States - Required COO must be noted at time of order 8421.29.0040
EA 2 Flange face - SAE Code 61 Double 2 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936716Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 5 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936717Q United States - Required COO must be noted at time of order 8421.29.0040
EA 2 Flange face - SAE Code 61 Double 5 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936717Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 10 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936718Q United States - Required COO must be noted at time of order 8421.29.0040
EA 2 Flange face - SAE Code 61 Double 10 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936718Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 20 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936719Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 20 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936719Q Special request, please call for COO Special request, please call for HTS
EA 2 NPT Single 10 micron 45 GPM (171 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936602Q Special request, please call for COO Special request, please call for HTS
EA 2 NPT Single 20 micron 45 GPM (171 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936715Q Special request, please call for COO Special request, please call for HTS
EA 2 NPT Double 2 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936716Q Special request, please call for COO Special request, please call for HTS
EA 2 NPT Double 5 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936717Q Special request, please call for COO Special request, please call for HTS
EA 2 NPT Double 10 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936718Q United States - Required COO must be noted at time of order 8421.29.0040
EA 2 NPT Double 20 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936719Q United States - Required COO must be noted at time of order 8421.29.0040
EA 1 1/2 NPT Single 2 micron 45 GPM (171 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936713Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 NPT Single 5 micron 45 GPM (171 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936714Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 NPT Single 5 micron 45 GPM (171 LPM) Plugged Indicator 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936714Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 NPT Single 20 micron 45 GPM (171 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936715Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 NPT Single 20 micron 45 GPM (171 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) SAE-4 drain port on bowl 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936715Q Special request, please call for COO Special request, please call for HTS
80CN102QEBE2KY324
Out of Stock - Lead Time Required
$874.24

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Single

2 micron

45 GPM (171 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936713Q

Special request, please call for COO

Special request, please call for HTS

80CN110QEBM2KY324
Out of Stock - Lead Time Required
$809.23

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Single

10 micron

45 GPM (171 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936602Q

United States - Required COO must be noted at time of order

8421.29.0040

80CN202QEBE2KY324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

2 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936716Q

Special request, please call for COO

Special request, please call for HTS

80CN205QEBE2KY324
Out of Stock - Lead Time Required
$936.97

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

5 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936717Q

United States - Required COO must be noted at time of order

8421.29.0040

80CN205QEBM2KY324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

5 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936717Q

Special request, please call for COO

Special request, please call for HTS

80CN210QEBE2KY324
Out of Stock - Lead Time Required
$928.19

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

10 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936718Q

United States - Required COO must be noted at time of order

8421.29.0040

80CN210QEBM2KY324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

10 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936718Q

Special request, please call for COO

Special request, please call for HTS

80CN220QEBE2KY324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

20 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936719Q

Special request, please call for COO

Special request, please call for HTS

80CN220QEBM2KY324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

20 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936719Q

Special request, please call for COO

Special request, please call for HTS

80CN110QEBM2KN324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 NPT

Single

10 micron

45 GPM (171 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936602Q

Special request, please call for COO

Special request, please call for HTS

80CN120QEBM2KN324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 NPT

Single

20 micron

45 GPM (171 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936715Q

Special request, please call for COO

Special request, please call for HTS

80CN202QEBM2KN324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 NPT

Double

2 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936716Q

Special request, please call for COO

Special request, please call for HTS

80CN205QEBM2KN324
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 NPT

Double

5 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936717Q

Special request, please call for COO

Special request, please call for HTS

80CN210QEBM2KN324
Out of Stock - Lead Time Required
$890.34

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 NPT

Double

10 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936718Q

United States - Required COO must be noted at time of order

8421.29.0040

80CN220QEBM2KN324
Out of Stock - Lead Time Required
$852.66

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 NPT

Double

20 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936719Q

United States - Required COO must be noted at time of order

8421.29.0040

80CN102QEBM2KN244
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 NPT

Single

2 micron

45 GPM (171 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936713Q

Special request, please call for COO

Special request, please call for HTS

80CN105QEBM2KN244
Out of Stock - Lead Time Required
$809.09

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 NPT

Single

5 micron

45 GPM (171 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936714Q

Special request, please call for COO

Special request, please call for HTS

80CN105QEBPKN244
Out of Stock - Lead Time Required
$743.83

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 NPT

Single

5 micron

45 GPM (171 LPM)

Plugged Indicator

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936714Q

Special request, please call for COO

Special request, please call for HTS

80CN120QEBE2KN244
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 NPT

Single

20 micron

45 GPM (171 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936715Q

Special request, please call for COO

Special request, please call for HTS

80CN120QEBM2KN244
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 NPT

Single

20 micron

45 GPM (171 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

SAE-4 drain port on bowl

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936715Q

Special request, please call for COO

Special request, please call for HTS

Showing 1 - 20 of 50
Parker 80CN Series Hydraulic and Lube Oil Medium Pressure Filter