Refine
FILTERSClear All

Element Length

Nominal Filter Micron Rating

Filter Media Type

Nominal Flow Rating

Bypass

Filter Media Code

Indicator Type

Operating Temperature

Seals

Click Image to Zoom
15P Series High Pressure Filter15P Series High Pressure Filter

15P Series High Pressure Filter

Parker 15P Series Hydraulic and Lube Oil High Pressure Filter

Email this page to a friend


Showing 1 - 9 of 9  
Part # Availability Price/UOM
15P102QBM2KS1221 N/A Call to Order
15P110QBE2KS1221 N/A Call to Order
15P110QHVE2KS1221 N/A Call to Order
++ 15P110QXBM2KS1221 Out of Stock - Lead Time Required $694.50
++ 15P202QBE2KS1221 Out of Stock - Lead Time Required $676.71
15P202QVPKS1221 N/A Call to Order
++ 15P205QVE2KS1221 Out of Stock - Lead Time Required $719.37
++ 15P205QHBM2KS1221 Out of Stock - Lead Time Required $688.77
15P210QVE2KS1221 N/A Call to Order
UOM Port Element Length Nominal Filter Rating Nominal Flow Rating Indicator Type Bypass Options Max Pressure - Fatigue MAOP Max Pressure - Non-Fatigue MAOP Seals Operating Temperature Replacement Element Country of Origin (COO) Harmonized Tariff (HTS)
EA 12 SAE Single 2 micron 10 GPM (38 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Nitrile -40F to 225F (-40C to 107C) 932610Q Special request, please call for COO Special request, please call for HTS
EA 12 SAE Single 10 micron 10 GPM (38 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Nitrile -40F to 225F (-40C to 107C) 932612Q Special request, please call for COO Special request, please call for HTS
EA 12 SAE Single 10 micron (2000 PSID High Collapse) 10 GPM (38 LPM) Electrical/Visual (DIN-43650 Connection) None No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Fluorocarbon -15F to 225F (-26C to 107C) 932615Q Special request, please call for COO Special request, please call for HTS
EA 12 SAE Single 10 micron (3000 PSID High Collapse) 10 GPM (38 LPM) Visual - Automatic Reset None No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Nitrile -40F to 225F (-40C to 107C) 933577Q United States - Required COO must be noted at time of order 8421.29.0040
EA 12 SAE Double 2 micron 15 GPM (57 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Nitrile -40F to 225F (-40C to 107C) 932616Q United States - Required COO must be noted at time of order 8421.29.0040
EA 12 SAE Double 2 micron 15 GPM (57 LPM) Plugged Indicator 50 PSI (3.5 bar) No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Fluorocarbon -15F to 225F (-26C to 107C) 932616Q Special request, please call for COO Special request, please call for HTS
EA 12 SAE Double 5 micron 15 GPM (57 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Fluorocarbon -15F to 225F (-26C to 107C) 932617Q United States - Required COO must be noted at time of order 8421.29.0040
EA 12 SAE Double 5 micron (2000 PSID High Collapse) 15 GPM (57 LPM) Visual - Automatic Reset None No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Nitrile -40F to 225F (-40C to 107C) 932620Q Special request, please call for COO Special request, please call for HTS
EA 12 SAE Double 10 micron 15 GPM (57 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 2000 psi (138 bar) 3000 psi (206.9 bar) Fluorocarbon -15F to 225F (-26C to 107C) 932618Q Special request, please call for COO Special request, please call for HTS
15P102QBM2KS1221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Single

2 micron

10 GPM (38 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Nitrile

-40F to 225F (-40C to 107C)

932610Q

Special request, please call for COO

Special request, please call for HTS

15P110QBE2KS1221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Single

10 micron

10 GPM (38 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Nitrile

-40F to 225F (-40C to 107C)

932612Q

Special request, please call for COO

Special request, please call for HTS

15P110QHVE2KS1221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Single

10 micron (2000 PSID High Collapse)

10 GPM (38 LPM)

Electrical/Visual (DIN-43650 Connection)

None

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Fluorocarbon

-15F to 225F (-26C to 107C)

932615Q

Special request, please call for COO

Special request, please call for HTS

15P110QXBM2KS1221
Out of Stock - Lead Time Required
$694.50

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Single

10 micron (3000 PSID High Collapse)

10 GPM (38 LPM)

Visual - Automatic Reset

None

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Nitrile

-40F to 225F (-40C to 107C)

933577Q

United States - Required COO must be noted at time of order

8421.29.0040

15P202QBE2KS1221
Out of Stock - Lead Time Required
$676.71

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Double

2 micron

15 GPM (57 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Nitrile

-40F to 225F (-40C to 107C)

932616Q

United States - Required COO must be noted at time of order

8421.29.0040

15P202QVPKS1221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Double

2 micron

15 GPM (57 LPM)

Plugged Indicator

50 PSI (3.5 bar)

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Fluorocarbon

-15F to 225F (-26C to 107C)

932616Q

Special request, please call for COO

Special request, please call for HTS

15P205QVE2KS1221
Out of Stock - Lead Time Required
$719.37

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Double

5 micron

15 GPM (57 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Fluorocarbon

-15F to 225F (-26C to 107C)

932617Q

United States - Required COO must be noted at time of order

8421.29.0040

15P205QHBM2KS1221
Out of Stock - Lead Time Required
$688.77

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Double

5 micron (2000 PSID High Collapse)

15 GPM (57 LPM)

Visual - Automatic Reset

None

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Nitrile

-40F to 225F (-40C to 107C)

932620Q

Special request, please call for COO

Special request, please call for HTS

15P210QVE2KS1221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

12 SAE

Double

10 micron

15 GPM (57 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

2000 psi (138 bar)

3000 psi (206.9 bar)

Fluorocarbon

-15F to 225F (-26C to 107C)

932618Q

Special request, please call for COO

Special request, please call for HTS

Showing 1 - 9 of 9
Parker 15P Series Hydraulic and Lube Oil High Pressure Filter

Updating...