Refine
FILTERSClear All

Nominal Filter Micron Rating

Filter Media Type

Bypass

Filter Media Code

Indicator Type

Options

Seals

Click Image to Zoom
WPF5 Series High Pressure FilterWPF5 Series High Pressure Filter

WPF5 Series High Pressure Filter

Parker WPF5 Series Hydraulic and Lube Oil High Pressure Filter

Email this page to a friend


Showing 1 - 17 of 17  
Part # Availability Price/UOM
++ WPF502QEBPKY241 Out of Stock - Lead Time Required $1,023.51
WPF502QEVE2KY241 N/A Call to Order
WPF502QEVM2KY241 N/A Call to Order
++ WPF502QEVPKY241 Out of Stock - Lead Time Required $1,023.51
++ WPF502QHBPXY242 Out of Stock - Lead Time Required $1,400.12
WPF502QHVE2KY242 N/A Call to Order
++ WPF502QHVPXY242 Out of Stock - Lead Time Required $1,400.12
++ WPF505QEBPKY241 Out of Stock - Lead Time Required $1,010.22
++ WPF505QEVE2KY241 Out of Stock - Lead Time Required $1,159.97
++ WPF505QEVM2KY241 Out of Stock - Lead Time Required $1,323.98
++ WPF505QEVPKY241 Out of Stock - Lead Time Required $1,010.22
++ WPF510QEBPKY241 Out of Stock - Lead Time Required $999.14
++ WPF510QEVE2KY241 Out of Stock - Lead Time Required $1,148.73
++ WPF510QEVM2KY241 Out of Stock - Lead Time Required $1,309.83
++ WPF510QEVPKY241 Out of Stock - Lead Time Required $999.14
WPF510QHVE2KY242 N/A Call to Order
WPF510QHVM2KY242 N/A Call to Order
UOM Port Element Length Nominal Filter Rating Nominal Flow Rating Indicator Type Bypass Options Max Pressure - Fatigue MAOP Max Pressure - Non-Fatigue MAOP Seals Operating Temperature Replacement Element Country of Origin (COO) Harmonized Tariff (HTS)
EA 1 1/2 Flange face - SAE Code 62 Single 2 micron 137 GPM (520 LPM) Plugged Indicator 50 PSI (3.5 bar) With Bypass 6000 psi (414 bar) 7000 psi (483 bar) Nitrile -15F to 250F (-26C to 135C) 941041Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 2 micron 137 GPM (520 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941041Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 2 micron 137 GPM (520 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941041Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 2 micron 137 GPM (520 LPM) Plugged Indicator 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941041Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 2 micron (2000 PSID High Collapse) 137 GPM (520 LPM) Plugged Indicator No Bypass and No Indicator (port plugged) No Bypass 6000 psi (414 bar) 7000 psi (483 bar) Nitrile -15F to 250F (-26C to 135C) 941052Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 2 micron (2000 PSID High Collapse) 137 GPM (520 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No Bypass 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941052Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 2 micron (2000 PSID High Collapse) 137 GPM (520 LPM) Plugged Indicator No Bypass and No Indicator (port plugged) No Bypass 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 135C) 941052Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 5 micron 137 GPM (520 LPM) Plugged Indicator 50 PSI (3.5 bar) With Bypass 6000 psi (414 bar) 7000 psi (483 bar) Nitrile -15F to 250F (-26C to 135C) 941042Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 5 micron 137 GPM (520 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941042Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 5 micron 137 GPM (520 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941042Q United States - Required COO must be noted at time of order 8421.29.0040
EA 1 1/2 Flange face - SAE Code 62 Single 5 micron 137 GPM (520 LPM) Plugged Indicator 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941042Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 10 micron 137 GPM (520 LPM) Plugged Indicator 50 PSI (3.5 bar) With Bypass 6000 psi (414 bar) 7000 psi (483 bar) Nitrile -15F to 250F (-26C to 135C) 941043Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 10 micron 137 GPM (520 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941043Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 10 micron 137 GPM (520 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941043Q United States - Required COO must be noted at time of order 8421.29.0040
EA 1 1/2 Flange face - SAE Code 62 Single 10 micron 137 GPM (520 LPM) Plugged Indicator 50 PSI (3.5 bar) No Option 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941043Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 10 micron (2000 PSID High Collapse) 137 GPM (520 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No Bypass 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941053Q Special request, please call for COO Special request, please call for HTS
EA 1 1/2 Flange face - SAE Code 62 Single 10 micron (2000 PSID High Collapse) 137 GPM (520 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) No Bypass 6000 psi (414 bar) 7000 psi (483 bar) Fluorocarbon -15F to 250F (-26C to 121C) 941053Q Special request, please call for COO Special request, please call for HTS
WPF502QEBPKY241
Out of Stock - Lead Time Required
$1,023.51

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

2 micron

137 GPM (520 LPM)

Plugged Indicator

50 PSI (3.5 bar)

With Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Nitrile

-15F to 250F (-26C to 135C)

941041Q

Special request, please call for COO

Special request, please call for HTS

WPF502QEVE2KY241
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

2 micron

137 GPM (520 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941041Q

Special request, please call for COO

Special request, please call for HTS

WPF502QEVM2KY241
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

2 micron

137 GPM (520 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941041Q

Special request, please call for COO

Special request, please call for HTS

WPF502QEVPKY241
Out of Stock - Lead Time Required
$1,023.51

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

2 micron

137 GPM (520 LPM)

Plugged Indicator

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941041Q

Special request, please call for COO

Special request, please call for HTS

WPF502QHBPXY242
Out of Stock - Lead Time Required
$1,400.12

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

2 micron (2000 PSID High Collapse)

137 GPM (520 LPM)

Plugged Indicator

No Bypass and No Indicator (port plugged)

No Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Nitrile

-15F to 250F (-26C to 135C)

941052Q

Special request, please call for COO

Special request, please call for HTS

WPF502QHVE2KY242
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

2 micron (2000 PSID High Collapse)

137 GPM (520 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941052Q

Special request, please call for COO

Special request, please call for HTS

WPF502QHVPXY242
Out of Stock - Lead Time Required
$1,400.12

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

2 micron (2000 PSID High Collapse)

137 GPM (520 LPM)

Plugged Indicator

No Bypass and No Indicator (port plugged)

No Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 135C)

941052Q

Special request, please call for COO

Special request, please call for HTS

WPF505QEBPKY241
Out of Stock - Lead Time Required
$1,010.22

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

5 micron

137 GPM (520 LPM)

Plugged Indicator

50 PSI (3.5 bar)

With Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Nitrile

-15F to 250F (-26C to 135C)

941042Q

Special request, please call for COO

Special request, please call for HTS

WPF505QEVE2KY241
Out of Stock - Lead Time Required
$1,159.97

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

5 micron

137 GPM (520 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941042Q

Special request, please call for COO

Special request, please call for HTS

WPF505QEVM2KY241
Out of Stock - Lead Time Required
$1,323.98

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

5 micron

137 GPM (520 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941042Q

United States - Required COO must be noted at time of order

8421.29.0040

WPF505QEVPKY241
Out of Stock - Lead Time Required
$1,010.22

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

5 micron

137 GPM (520 LPM)

Plugged Indicator

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941042Q

Special request, please call for COO

Special request, please call for HTS

WPF510QEBPKY241
Out of Stock - Lead Time Required
$999.14

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

10 micron

137 GPM (520 LPM)

Plugged Indicator

50 PSI (3.5 bar)

With Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Nitrile

-15F to 250F (-26C to 135C)

941043Q

Special request, please call for COO

Special request, please call for HTS

WPF510QEVE2KY241
Out of Stock - Lead Time Required
$1,148.73

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

10 micron

137 GPM (520 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941043Q

Special request, please call for COO

Special request, please call for HTS

WPF510QEVM2KY241
Out of Stock - Lead Time Required
$1,309.83

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

10 micron

137 GPM (520 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941043Q

United States - Required COO must be noted at time of order

8421.29.0040

WPF510QEVPKY241
Out of Stock - Lead Time Required
$999.14

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

10 micron

137 GPM (520 LPM)

Plugged Indicator

50 PSI (3.5 bar)

No Option

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941043Q

Special request, please call for COO

Special request, please call for HTS

WPF510QHVE2KY242
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

10 micron (2000 PSID High Collapse)

137 GPM (520 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941053Q

Special request, please call for COO

Special request, please call for HTS

WPF510QHVM2KY242
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

1 1/2 Flange face - SAE Code 62

Single

10 micron (2000 PSID High Collapse)

137 GPM (520 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

No Bypass

6000 psi (414 bar)

7000 psi (483 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

941053Q

Special request, please call for COO

Special request, please call for HTS

Showing 1 - 17 of 17
Parker WPF5 Series Hydraulic and Lube Oil High Pressure Filter

Application: Aircraft ground support, injection molding, mining, mobile ag, mobile construction, oil & gas exploration, power generation, primary metals, and refuse trucks.
Updating...