Refine
FILTERSClear All

Element Length

Nominal Filter Micron Rating

Nominal Flow Rating

Bypass

Filter Media Code

Indicator Type

Operating Temperature

Seals

Click Image to Zoom
80CN Series Medium Pressure Filter80CN Series Medium Pressure Filter

80CN Series Medium Pressure Filter

Parker 80CN Series Hydraulic and Lube Oil Medium Pressure Filter

Email this page to a friend


Showing 1 - 8 of 8  
Part # Availability Price/UOM
80CN110QEBM2GY3221 N/A Call to Order
80CN110QEBM2KY3221 N/A Call to Order
80CN202QEBE2KY3221 N/A Call to Order
80CN205QEBE2KY3221 N/A Call to Order
80CN210QEBE2KY3221 N/A Call to Order
80CN210QEBM2KY3221 N/A Call to Order
++ 80CN220QEBE2KY3221 Out of Stock - Lead Time Required $922.91
80CN220QEVPKY3221 N/A Call to Order
UOM Port Element Length Nominal Filter Rating Nominal Flow Rating Indicator Type Bypass Options Max Pressure - Fatigue MAOP Max Pressure - Non-Fatigue MAOP Seals Operating Temperature Replacement Element Country of Origin (COO) Harmonized Tariff (HTS)
EA 2 Flange face - SAE Code 61 Single 10 micron 45 GPM (171 LPM) Visual - Automatic Reset 25 PSI (1.7 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936602Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Single 10 micron 45 GPM (171 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936602Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 2 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936716Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 5 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936717Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 10 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936718Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 10 micron 70 GPM (265 LPM) Visual - Automatic Reset 50 PSI (3.5 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936718Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 20 micron 70 GPM (265 LPM) Electrical/Visual (DIN-43650 Connection) 50 PSI (3.5 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Nitrile -40F to 225F (-40C to 107C) 936719Q Special request, please call for COO Special request, please call for HTS
EA 2 Flange face - SAE Code 61 Double 20 micron 70 GPM (265 LPM) Plugged Indicator 50 PSI (3.5 bar) No bypass and drain port 800 psi (55.2 bar) 1000 psi (69 bar) Fluorocarbon -15F to 250F (-26C to 121C) 936719Q Special request, please call for COO Special request, please call for HTS
80CN110QEBM2GY3221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Single

10 micron

45 GPM (171 LPM)

Visual - Automatic Reset

25 PSI (1.7 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936602Q

Special request, please call for COO

Special request, please call for HTS

80CN110QEBM2KY3221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Single

10 micron

45 GPM (171 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936602Q

Special request, please call for COO

Special request, please call for HTS

80CN202QEBE2KY3221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

2 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936716Q

Special request, please call for COO

Special request, please call for HTS

80CN205QEBE2KY3221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

5 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936717Q

Special request, please call for COO

Special request, please call for HTS

80CN210QEBE2KY3221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

10 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936718Q

Special request, please call for COO

Special request, please call for HTS

80CN210QEBM2KY3221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

10 micron

70 GPM (265 LPM)

Visual - Automatic Reset

50 PSI (3.5 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936718Q

Special request, please call for COO

Special request, please call for HTS

80CN220QEBE2KY3221
Out of Stock - Lead Time Required
$922.91

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

20 micron

70 GPM (265 LPM)

Electrical/Visual (DIN-43650 Connection)

50 PSI (3.5 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Nitrile

-40F to 225F (-40C to 107C)

936719Q

Special request, please call for COO

Special request, please call for HTS

80CN220QEVPKY3221
N/A
Call to Order

UOM:

Port:

Element Length:

Nominal Filter Rating:

Nominal Flow Rating:

Indicator Type:

Bypass:

Options:

Max Pressure - Fatigue MAOP:

Max Pressure - Non-Fatigue MAOP:

Seals:

Operating Temperature:

Replacement Element:

Country of Origin (COO):

Harmonized Tariff (HTS):

EA

2 Flange face - SAE Code 61

Double

20 micron

70 GPM (265 LPM)

Plugged Indicator

50 PSI (3.5 bar)

No bypass and drain port

800 psi (55.2 bar)

1000 psi (69 bar)

Fluorocarbon

-15F to 250F (-26C to 121C)

936719Q

Special request, please call for COO

Special request, please call for HTS

Showing 1 - 8 of 8
Parker 80CN Series Hydraulic and Lube Oil Medium Pressure Filter

Updating...